Passive House Heating Demand Calculator

Estimate a building's annual heating demand in kWh per square meter per year and its peak heating load from floor area, U-values, window performance, temperature difference, and heat recovery. It checks the result against Passive House limits.

Reviewed and updated

How to use
  1. Enter the floor area and envelope U-values.
  2. Add the window performance and temperature difference.
  3. Set the heat-recovery efficiency.
Estimates based on typical values; your real usage and rates will vary.
Was this helpful?

The number that defines the standard

Annual heating demand 15 kWh/m²·yr

This is the core Passivhaus criterion, calculated over the treated floor area. It comes out of a heat balance: transmission and ventilation losses, minus the solar and internal heat gains the building already receives. Meet it and the house needs about five to ten times less heating energy than a conventional build of the same size.

Passivhaus vs a conventional house

The 15 kWh/m² limit and the 10 W/m² peak load are what set the standard apart. Both sit far below normal construction.

15 kWh/m²·yrPassivhaus
75–150 kWh/m²·yrConventional

Heating energy per year. A Passive House uses roughly 75–90% less than a standard home, which is why its peak load falls from 50–100 W/m² to just 10.

The full set of criteria

CriterionPassivhaus limitConventional
Heating demand≤ 15 kWh/m²·yr75–150
Peak heating load≤ 10 W/m²50–100
Airtightness≤ 0.6 ACH₅₀3–10
Heat recovery≥ 75%none typical
Wall U-value≤ 0.15 W/m²K0.3–0.5
Window U-value≤ 0.80 W/m²K1.4–2.8

Airtightness is verified with a blower-door test. The heat recovery ventilation is what makes the low demand possible: it reclaims 75–85% of the warmth in outgoing air instead of throwing it away.

Common questions

What is the Passivhaus heating demand limit?

A certified Passive House must use no more than 15 kWh per square metre of floor area per year for heating. That is the headline criterion, alongside a peak heating load of 10 W/m2 and airtightness of 0.6 air changes per hour at 50 Pa.

How much less energy is that than a normal house?

Roughly 75 to 90% less for heating and cooling. A conventional home often needs 75 to 150 kWh/m2 per year; a Passive House stays at or under 15. The peak load drops from 50 to 100 W/m2 down to 10.

Does a Passive House still need a heating system?

Yes, but a small one. Because peak demand is so low, a 1 to 2 kW heater, a modest heat pump or a small gas boiler is enough where a conventional house would need 5 to 10 kW or more.